APC AP7921B Rack PDU Switched 1U 16A 208/230V
Model
AP7921B
Location | Availability |
---|---|
Online (Delivery) | Available from Supplier (2 to 7 Working Days) |
Notting Hill (Pickup) | Available from Supplier (2 to 7 Working Days) |
Preston (Pickup) | Available from Supplier (2 to 7 Working Days) |
West Melbourne (Pickup) | Available from Supplier (2 to 7 Working Days) |
$1,653.00
RACK PDU SWITCHED 1U 16A 208/230V (8)C13
Switched Rack PDUFeatures & Benefits
Marketing Features
-
Remote Management CapabilitiesFull-featured network management interfaces that provide standards-based management via Web, SNMP, and Telnet. Allows users to access, configure, and manage units from remote locations to save valuable time. Associated with this feature is the ability to quickly and easily upgrade the firmware via network download to installed units for future product enhancements.
-
Local Current Monitoring DisplayThe aggregate current draw per power distribution unit is displayed on the unit via a digital display. The local digital display helps installers avoid overloaded circuits by providing a visible warning when the current draw is close to the maximum amperage draw of the strip.
-
Remote Individual Outlet ControlRemotely manage outlets so users can turn outlets off that are not in use (prevent overloads) or recycle power to locked-up equipment (minimize costly downtime and avoid travel time to equipment).
-
Alarm ThresholdsDefine alarm thresholds in order to avoid overloaded circuits. Network and visual alarms inform the user of possible problems.
-
Power DelaysAllows users to configure the sequence in which power is turned on or off for each outlet. This helps avoid in-rushes at start-up, which can cause overloaded circuits and dropped loads. Sequencing also allows users to predetermine which piece of equipment is turned on first so other equipment dependant on that unit will function properly.
Availability
-
Local Current Monitoring DisplayThe aggregate current draw per rack PDU is displayed on the unit via a digital display. The local digital display helps installers avoid overloaded circuits by providing a visible warning when the current draw is close to the maximum amperage draw of the strip. (Available on designated SKUs only)
-
Power DelaysAllows users to configure the sequence in which power is turned on or off for each outlet. This helps avoid in-rushes at start-up, which can cause overloaded circuits and dropped loads. Sequencing also allows users to predetermine which piece of equipment is turned on first so other equipment dependant on that unit will function properly.
-
Load indicator LEDIndicates overload and warning conditions based on the user-defined alarm thresholds. Alerts users of potential overloaded circuits.
-
Flash UpgradeableQuickly and easily upgrade firmware via network download for future product enhancements. Eliminates the need to replace products already installed in the field when new features are released. (Note: Networked units only)
-
Integrates with StruxureWare Data Center ExpertAn IT-ready, scalable access monitoring system that collects, organizes, and distributes critical alerts, surveillance video and key information, providing a unified view of complex physical infrastructure environments from anywhere on the network
-
Network Management CapabilitiesFull-featured network management interfaces that provide standards-based management via Web, SNMP, and Telnet. Allows users to access, configure, and manage rack PDUs from remote locations to save valuable time. Associated with this feature is the ability to quickly and easily upgrade the firmware via network download to installed units for future product enhancements.
-
Remote Individual Outlet ControlRemotely manage outlets so users can turn outlets off that are not in use (prevent overloads) or recycle power to locked-up equipment (minimize costly downtime and avoid travel time to equipment).
-
Alarm ThresholdsDefine alarm thresholds in order to avoid overloaded circuits. Network and visual alarms inform the user of possible problems. (Note: Only available on units with the current monitoring capabilities. Please see SKU specifications for availability)
Agility
-
Rack-MountableIncludes horizontal, vertical, and toolless-mount varieties. Puts power where it is needed most - in the racks near the equipment.
-
Single input power sourceSupply power from one branch whip to multiple pieces of equipment, conveniently powering rack-mount equipment. Saves time and money during installation by using one branch whip and standard connections.
-
Wide range of input and output connectionsProduct family includes a variety of input and output connections to distribute 120V, 208V, or 230V power to multiple outlets. Having a variety of inputs and outputs allow users to adapt to varying power requirements. APC offers units that bring up to 14.4kW using a single branch whip.
Output
-
Nominal Output Voltage208V , 230V
-
Maximum Total Current Draw16
-
Output Connections(8) IEC 320 C13 (Battery Backup)
Input
-
Nominal Input Voltage200V , 208V , 230V
-
Input frequency50/60 Hz
-
Input ConnectionsIEC-320 C20
-
Cord Length2.5meters
-
Acceptable Input Voltage200-240VAC
-
Number of Power Cords1
-
Load Capacity3680VA
-
Maximum Input Current20A
-
Regulatory Derated Input Current (North America)16A
Physical
-
Maximum Height44mm , 4.4cm
-
Maximum Width445mm , 44.5cm
-
Maximum Depth108mm , 10.8cm
-
Rack Height1U
-
Net Weight2.27kg
-
Shipping weight3.45kg
-
Shipping Height70mm , 7.0cm
-
Shipping Width470mm , 47.0cm
-
Shipping Depth343mm , 34.3cm
-
ColorBlack
Environmental
-
Operating Environment0 - 45 °C
-
Operating Relative Humidity0 - 95 %
-
Operating Elevation0-3000meters
-
Storage Temperature-25 - 65 °C
-
Storage Relative Humidity0 - 95 %
-
Storage Elevation0-15000meters
Conformance
-
ApprovalscUL Listed, CE, CSA, EN 55022 Class A, EN 55024, EN 61000-3-2, EN 61000-3-3, GOST, IRAM, MIC, UL 60950, UL Listed, VDE, VCCI
-
Standard warranty2 years repair or replace
Sustainable Offer Status
-
RoHSCompliant
-
REACHREACH: Contains No SVHCs
-
PEPAvailable in Documentation tab
-
EOLIAvailable in Documentation tab
-
Battery DirectiveCompliant
-
Battery Notests_Battery_Notes
-
Other Environmental ComplianceChina RoHS